{"product_id":"recosyn-max-forte-n-1-x-2-ml","title":"Recosyn Max forte N 1x 2.0 ml","description":"\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/stakonmed.de\/collections\/recosyn\" title=\"Recosyn | Gelenkspritzen | StakonMed\"\u003e\u003cspan\u003eRecosyn\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e® \u003c\/span\u003e\u003cspan\u003eMax forte N\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSodium hyaluronate intra-articular plus niacinamide\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eThe prefilled syringe contains a hydrogel made of high-molecular and highly purified sodium hyaluronate from bacterial fermentation. The product serves to improve viscosity in the intra-articular connective tissue. It has undergone steam sterilization for injectable products and is non-pyrogenic.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eRecosyn\u003c\/span\u003e\u003cspan\u003e® \u003c\/span\u003e\u003cspan\u003eMax forte N \u003c\/span\u003e\u003cspan\u003econtains 2 ml aqueous, physiological phosphate buffer solution with \u003c\/span\u003e\u003cspan\u003e44 mg sodium hyaluronate. The sodium hyaluronate hydrogel is contained in \u003c\/span\u003e\u003cspan\u003ea weak, sterile, isotonic, and apyrogenic phosphate-buffered saline solution with a pH of 7.2 (6.8 – 7.4) in sufficient volume for injection. The fill volume is 2 ml.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eThe chemical components are listed in the table (weight per volume as mg substance per 1 ml hydrogel):\u003cbr\u003e(a) Sodium hyaluronate, (b) Sodium chloride, (c) Disodium hydrogen phosphate 2 H\u003c\/span\u003e\u003cspan\u003e2\u003c\/span\u003e\u003cspan\u003eO,\u003cbr\u003e(d) Sodium dihydrogen phosphate 2 H\u003c\/span\u003e\u003cspan\u003e2\u003c\/span\u003e\u003cspan\u003eO, (e) Water for injection, (f) Niacinamide\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eProperties and mode of action\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eHyaluronic acid, a widespread glycosaminoglycan, is an essential component \u003c\/span\u003e\u003cspan\u003ehealthy synovial fluid. This natural biopolymer provides viscoelasticity and\u003c\/span\u003e\u003cspan\u003eenables pain-free physiological movements thanks to its lubricating, shock-absorbing properties. Additionally, it supplies nutrients to the cartilage. The \u003c\/span\u003e\u003cspan\u003eRecosyn\u003c\/span\u003e\u003cspan\u003e® \u003c\/span\u003e\u003cspan\u003eMax forte N \u003c\/span\u003e\u003cspan\u003econtained sodium hyaluronate is a salt of hyaluronic acid.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eIndications\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003ePain and limitation of joint mobility in degenerative changes of the knee joint and other synovial joints, including osteoarthritis.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eContraindications\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe product must not be used in patients\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e- with known hypersensitivity to any of the components.\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e- with inflammation in the joint.\u003cbr\u003e- with septic arthritis.\u003cbr\u003e- with skin infections or skin diseases in the injection area.\u003cbr\u003e- with natural or medication-induced coagulation disorders such as hemophilia or when using anticoagulants like Marcumar (phenprocoumon) or Coumadin (warfarin).\u003cbr\u003eSince there are no clinical data on the use of hyaluronic acid in children, pregnant or breastfeeding women, use in these patients is not recommended.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003ePrecautions\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eSince septic arthritis can be a serious complication of the treatment, please observe all precautions usually necessary for surgical procedures. Injections of the hydrogel must be administered directly into the joint cavity; injections into blood vessels and surrounding tissue must be avoided.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eDo not use if the prefilled syringe or sterile packaging is damaged.\u003cbr\u003eThe opened product must not be resterilized, resealed, or reused. It is intended for use by a single patient at a single application session.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003ePossible side effects\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eNo adverse side effects were observed in biocompatibility tests with the product. Local reactions such as pain, redness, warmth, and swelling may occur at the treated joint. These reactions can be reduced by cooling the treated area with an ice pack for 5 to 10 minutes after the injection. During the first days of treatment, the simultaneous oral intake of pain and anti-inflammatory medications (NSAIDs) may be beneficial. Treatment should be discontinued in case of severe pain or inflammation. Management of adverse reactions should only be carried out under the supervision of the treating physician. Immediately after the injection, strenuous physical activity should be avoided and other instructions from the doctor followed.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eMedical personnel inform the patient about possible adverse events related to the product and advise that any side effect or complication must be reported to a doctor immediately.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003ePharmacological and chemical interactions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eSo far, there are no data on the incompatibility of the product with other solutions for intra-articular use.\u003cbr\u003eThere is a chemical incompatibility between sodium hyaluronate and quaternary ammonium compounds such as benzalkonium chloride, which can lead to crystalline precipitation. Therefore, this product must never come into contact with surgical instruments or other products that contain these or have been rinsed with solutions containing quaternary ammonium compounds as biocidal preservatives.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eDosage, type, and duration of use\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eThe prefilled syringe is to be removed from its packaging. The protective cap is to be removed from the Luer-Lock thread and a suitable sterile injection needle screwed onto the syringe. The use of a single-use needle is recommended. Air should be evacuated from the needle before injection. The skin area intended for injection must be cleaned with an appropriate topical antiseptic. In the case of joint effusion, it is recommended before the injection of \u003c\/span\u003e\u003cspan\u003eRecosyn\u003c\/span\u003e\u003cspan\u003e® \u003c\/span\u003e\u003cspan\u003eMax forte N \u003c\/span\u003e\u003cspan\u003efirst reduce the effusion by aspiration and examine it for bacterial etiology. The hydrogel can be injected intraarticularly 1 to 5 times at intervals determined by the physician. The beneficial effects of a treatment last at least 6 months. Treatment cycles can be repeated if necessary.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eDepending on the fill volume, multiple joints of a patient can be treated simultaneously. Unused product must be disposed of.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eDosage form\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eA box containing one prefilled syringe of 2 ml.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eShelf life\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eThe product must not be used after the expiration date. The expiration date (month\/year) is printed on the syringe blister and on the box.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eStorage instructions\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"section\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003eThe product should be stored dry between 2° and 25°C, protected from light and impact, in the original packaging. Accordingly, observe the warning symbols on the packaging.\u003cbr\u003eKeep the product out of reach of children.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eRecommended user group\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIntended exclusively for use by physicians.\u003cbr\u003eFor single use only. Do not resterilize. Do not use or attempt to reseal syringes, needles, and hydrogel from open or damaged packaging.\u003cbr\u003eSyringe contents are non-toxic and non-flammable.\u003cbr\u003eUsing a product from damaged packaging or reusing it on other patients or the same patient at a different time does not guarantee the intended properties and sterility. Otherwise, it can\u003c\/span\u003e\u003cspan\u003ea possible transmission of material contamination and pathogens from the \u003c\/span\u003e\u003cspan\u003eEnvironment, the clinical area, or (other) patients may suffer health complications. Resealing or resterilizing does not constitute an allowed or guaranteed restoration of the usable condition.\u003cbr\u003eUnused syringes and their contents are not infectious and can be disposed of before or after the expiration date, observing national and local regulations. Used syringes and needles must be treated as epidemiologically hazardous waste, and national and local regulations for safe use and disposal must be followed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003erev. 03\/2022-V02 rec\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Recordati Pharma GmbH","offers":[{"title":"Default Title","offer_id":47355880997204,"sku":"134","price":94.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/8756\/8212\/files\/recosyn-max-forte-n-recordati-pharma-gmbh-gelenkspritzen-stakonmed-544861.jpg?v=1772215337","url":"https:\/\/stakonmed.com\/products\/recosyn-max-forte-n-1-x-2-ml","provider":"StakonMed","version":"1.0","type":"link"}